CANBlue config software Introduction_GCAN
3. CANBlue config software 3.1 Configuration Disconnect the GCAN-203 power supply. We can connect to GCAN-203 and computer with USB. When GCAN-203 is configuring, no external power is required. GCAN-203 factory setting: CAN-Bus baud is 250K, working mode is normal mode, name is SN number, password is 1234. 3.2 Software connection Open "CANBlue Config" software in the " ②CANBlue 模块配置软件" document to configure the converter. Click "Connect" to connect the converter. The connection is shown ...
Introduce The Product Of Bluetooth-CAN converter_GCAN
1. Introduction 1.1 Overview GCAN-203 has a standard CAN-Bus interface. GCAN-203 can send CAN-Bus date to other equipment with Bluetooth. 1.2 Properties at a glance CAN-Bus baud rates range from 5Kbps to 1Mbps CAN-Bus isolation module insulation voltage: DC 1500V Maximum data traffic: 300 frames per second Bluetooth using 2.0 Power supply: 9~30V (20mA,24V DC) Installation method: DIN rail Working temperature range: -40 ℃ ~ +85 ℃; Size: (L) 112mm * (W) 70mm * (H) ...
Baud rate modification of Ethernet-CAN converter_GCAN
7 Baud rate modification online 7.1 Function Description In TCP Sever mode, GCAN-202 supports CAN-Bus baud rate modification online via Ethernet. Write the instructions into the upper computer to achieve modification of baud rate. It’s more concise and faster. 7.2 Format Description The instructions should be sent via Ethernet, as shown in table. Only Byte6, 7, 8, 10 can be modified. Byte6, Byte7: 02 01 means baud rate set; 0B 03 takes effect immediately. Byte8: ...
Software usage of Ethernet-CAN converter_GCAN
5 Usage of "CANet test" software This software can test some basic functions of GCAN-202 if are normal in TCP Server mode. User will be supplied some basic VB routine to develop testing system by themselves. Input the IP address and Port Number of GCAN-202, and click "Connect" to connect the equipment. 6 Usage of "Net Assist" software In three modes (TCP Sever, TCP Client, UDP), "Net Assist" can provide to test receiving/transmitting data function. ...
Use Of CANet Config software_GCAN
4 CANet Config software The GCAN-202 can configure parameters by "CANet Config" software, can set working mode, IP address, CAN working mode, CAN’s baud rate and other basic parameters. 4.1 Connection IP address must be filled when connecting to GCAN-202. If forget it, please restore factory settings and the default IP is 192.168.1.10. See chapter 3.1.1 for details.Click "Connect", and it shows the following software interface.The meaning of the button: "Connect" - connect the converter ...
Use Of Ethernet-CAN converter_GCAN
3. converter used GCAN-202 converter uses a network cable to connect to PC, uses +9 ~ 30V DC power supply(recommended + 12V or + 24V power supply), uses the "CANet Config" software to configure. 3.1 Restore the factory settings Default IP of GCAN-202 is 192.168.1.10, gateway is 255.255.255.0. If the user has modified the IP and forget it. By pressing the reset button, you can restore the factory settings.After GCAN-202 is powered on, you can ...
Introduce The Product Of Ethernet-CAN converter_GCAN
1. Introduction 1.1 Overview The GCAN-202 is a converter that integrates two CAN interfaces and one Ethernet interface. Using GCAN-202, users can connect CAN-Bus network and Ethernet, extends the application scope of CAN-Bus.1.2 Properties at a glance Power supply: 9~30V(50mA, 24V DC) Working temperature range from -40 to 85 °C CAN-Bus supports CAN2.0A and CAN2.0B frame format, conform to ISO/DIS 11898 standards CAN baud rates range from 5Kbps to 1Mbps CAN-Bus interface with electrical isolation CAN-Bus ...
Example of 232/485-CAN converter_GCAN
4 Examples 4.1 Transparent conversion 1. Serial port→CAN GCAN-201 will send the serial data to CAN-Bus immediately if GCAN-201 receive the serial data.E.g. Serial data 11 22 33 44 55 66 77 88 converts to CAN-Bus. Frame ID is the configuration for“发送标识符” which users have set. Frame data is 11 22 33 44 55 66 77 88. 2. CAN→Serial port GCAN-201 will send the CAN data to serial port immediately if GCAN-201 receive the CAN ...
Configuration Instructions Of 232/485-CAN Converter_GCAN
3 Configuration instructions 3.1 Ready to configure First, power on the converter, then using a thimble click reset button at the side of the DB9 interface module. Module of COM light and CAN light flashing interactively, that module to enter configuration mode. After connecting the module of the RS232 interface and PC, enter the device manager to find the serial port Number. Note: the serial NO.(COM) can be modified in device manager interface, GCAN-201 can ...
Introduce The Product Of Ethernet-CAN converter_GCAN
1. Introduction 1.1 Overview The GCAN-202 is a converter that integrates two CAN interfaces and one Ethernet interface. Using GCAN-202, users can connect CAN-Bus network and Ethernet, extends the application scope of CAN-Bus.1.2 Properties at a glance Power supply: 9~30V(50mA, 24V DC) Working temperature range from -40 to 85 °C CAN-Bus supports CAN2.0A and CAN2.0B frame format, conform to ISO/DIS 11898 standards CAN baud rates range from 5Kbps to 1Mbps CAN-Bus interface with electrical isolation CAN-Bus ...